General Instructions for 12V DC Systems
-
Check battery voltage. If voltage is 9 volts or less, do not operate power unit. Charge battery to 12 volts.
-
Check to see that the motor is wired correctly to the starter switch and all other control wires have tight connections.
-
Check ground wire for good connection.
-
Check reservoir oil level.
-
Do not tamper with relief valve. It is factory preset to a specified pressure and wired. Cutting this wire voids warranty.
Symptoms
-
Unit will not start
-
See causes 1, 2, 7.
-
-
Unit drifts when power is off
-
See causes 3, 4, 5.
-
-
Slow cylinder travel
-
See causes 1, 2, 4, 5.
-
-
Unit will not lower
-
See causes 2, 3.
-
Probable Cause
-
Improper voltage to motor
-
See solutions 1, 4, 5.
-
-
Improper ground
-
See solutions 1, 6, 7.
-
-
Improper voltage to valves
-
See solutions 1, 6.
-
-
Leakage through solenoid valves
-
See solutions 3, 4.
-
-
Internal leakage at cylinder
-
See solutions 4, 5.
-
-
Insufficient oil to pump inlet
-
See solutions 2, 3, 5.
-
-
Pump seized or locked
-
See solutions 4, 5.
-
Possible Solution
-
Check wiring to ensure that all connections are tight.
-
Keep oil reservoir full and clean.
-
Flush and clean cartridge valves and/or hydraulic system.
-
Replace components.
-
Return for necessary repair.
-
Check for clean, tight, metal-to-metal contact on wire connections.
-
Make sure the nut on top of the solenoid valve coil is tightened to 40 in. lb maximum.